smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.2-RELEASE-p3 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     WD Blue SA510 M.2 2280 250GB
Serial Number:    --
LU WWN Device Id: 5 001b44 ...
Firmware Version: 52020100
User Capacity:    250,059,350,016 bytes [250 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Form Factor:      M.2
TRIM Command:     Available, deterministic
Device is:        Not in smartctl database 7.3/5528
ATA Version is:   ACS-4, ACS-2 T13/2015-D revision 3
SATA Version is:  SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Thu May 15 23:21:10 2025 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM feature is:   Disabled
Rd look-ahead is: Enabled
Write cache is:   Enabled
DSN feature is:   Unavailable
ATA Security is:  Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00)	Offline data collection activity
					was never started.
					Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(    0) seconds.
Offline data collection
capabilities: 			 (0x71) SMART execute Offline immediate.
					No Auto Offline data collection support.
					Suspend Offline collection upon new
					command.
					No Offline surface scan supported.
					Self-test supported.
					Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   1) minutes.
Extended self-test routine
recommended polling time: 	 (  10) minutes.
Conveyance self-test routine
recommended polling time: 	 (   1) minutes.

SMART Attributes Data Structure revision number: 0
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  5 Reallocated_Sector_Ct   -O--CK   100   100   010    -    0
  9 Power_On_Hours          -O--CK   100   100   000    -    896
 12 Power_Cycle_Count       -O--CK   100   100   000    -    103
165 Unknown_Attribute       -O--CK   100   100   000    -    9114078218592
166 Unknown_Attribute       -O--CK   100   100   000    -    19
167 Unknown_Attribute       -O--CK   100   100   000    -    50
168 Unknown_Attribute       -O--CK   100   100   000    -    45
169 Unknown_Attribute       -O--CK   100   100   000    -    132
170 Unknown_Attribute       -O--CK   100   100   000    -    0
171 Unknown_Attribute       -O--CK   100   100   000    -    0
172 Unknown_Attribute       -O--CK   100   100   000    -    0
173 Unknown_Attribute       -O--CK   100   100   005    -    27
174 Unknown_Attribute       -O--CK   100   100   000    -    4
184 End-to-End_Error        -O--CK   100   100   097    -    0
187 Reported_Uncorrect      -O--CK   100   100   000    -    73
188 Command_Timeout         -O--CK   100   100   000    -    0
194 Temperature_Celsius     -O---K   100   100   014    -    47 (Min/Max 18/71)
199 UDMA_CRC_Error_Count    -O--CK   100   100   000    -    0
230 Unknown_SSD_Attribute   -O--CK   100   100   000    -    3384456250132
232 Available_Reservd_Space PO--CK   100   100   004    -    80
233 Media_Wearout_Indicator -O--CK   100   100   000    -    6909
234 Unknown_Attribute       -O--CK   100   100   000    -    13518
241 Total_LBAs_Written      ----CK   253   253   000    -    8193
242 Total_LBAs_Read         ----CK   253   253   000    -    165
244 Unknown_Attribute       -O--CK   100   100   000    -    0
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 1
SMART           Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00       GPL,SL  R/O      1  Log Directory
0x01           SL  R/O      1  Summary SMART error log
0x02           SL  R/O      1  Comprehensive SMART error log
0x03       GPL     R/O     16  Ext. Comprehensive SMART error log
0x04       GPL,SL  R/O      8  Device Statistics log
0x06           SL  R/O      1  SMART self-test log
0x07       GPL     R/O      1  Extended self-test log
0x09           SL  R/W      1  Selective self-test log
0x10       GPL     R/O      1  NCQ Command Error log
0x11       GPL     R/O      1  SATA Phy Event Counters log
0x30       GPL,SL  R/O      9  IDENTIFY DEVICE data log
0x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
0xa0-0xa1  GPL,SL  VS       1  Device vendor specific log
0xa2       GPL,SL  VS       2  Device vendor specific log
0xa3-0xa7  GPL,SL  VS       1  Device vendor specific log
0xde       GPL,SL  VS       1  Device vendor specific log

Warning! SMART Extended Comprehensive Error Log Structure error: invalid SMART checksum.
SMART Extended Comprehensive Error Log Version: 1 (16 sectors)
Device Error Count: 73 (device log contains only the most recent 64 errors)
	CR     = Command Register
	FEATR  = Features Register
	COUNT  = Count (was: Sector Count) Register
	LBA_48 = Upper bytes of LBA High/Mid/Low Registers ]  ATA-8
	LH     = LBA High (was: Cylinder High) Register    ]   LBA
	LM     = LBA Mid (was: Cylinder Low) Register      ] Register
	LL     = LBA Low (was: Sector Number) Register     ]
	DV     = Device (was: Device/Head) Register
	DC     = Device Control Register
	ER     = Error register
	ST     = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 73 [8] occurred at disk power-on lifetime: 896 hours (37 days + 8 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 00 06 09 22 b0 40 08  Error: UNC at LBA = 0x060922b0 = 101262000

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  60 00 58 00 a8 00 00 06 09 22 b0 40 08     00:00:29.060  READ FPDMA QUEUED
  61 00 10 00 a0 00 00 1d 1c 56 10 40 08     00:00:29.060  WRITE FPDMA QUEUED
  61 00 10 00 98 00 00 1d 1c 54 10 40 08     00:00:29.060  WRITE FPDMA QUEUED
  61 00 10 00 90 00 00 01 08 2a 10 40 08     00:00:29.060  WRITE FPDMA QUEUED
  60 00 10 00 88 00 00 1d 1c 56 10 40 08     00:00:29.060  READ FPDMA QUEUED

Error 72 [7] occurred at disk power-on lifetime: 896 hours (37 days + 8 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 00 06 09 22 b0 46 08  Error: UNC at LBA = 0x060922b0 = 101262000

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  c8 00 00 00 58 00 00 00 09 22 b0 46 08     00:00:29.025  READ DMA
  60 00 58 00 d8 00 00 06 09 22 b0 40 08     00:00:29.025  READ FPDMA QUEUED
  60 00 10 00 d0 00 00 08 89 9e 20 40 08     00:00:29.025  READ FPDMA QUEUED
  60 00 18 00 c8 00 00 06 09 20 a8 40 08     00:00:29.025  READ FPDMA QUEUED
  60 00 08 00 c0 00 00 06 0b 60 60 40 08     00:00:29.025  READ FPDMA QUEUED

Error 71 [6] occurred at disk power-on lifetime: 896 hours (37 days + 8 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 00 06 09 22 b0 46 08  Error: UNC at LBA = 0x060922b0 = 101262000

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  c8 00 00 00 58 00 00 00 09 22 b0 46 08     00:00:28.990  READ DMA
  60 00 58 00 d8 00 00 06 09 22 b0 40 08     00:00:28.990  READ FPDMA QUEUED
  60 00 10 00 d0 00 00 08 89 9e 20 40 08     00:00:28.990  READ FPDMA QUEUED
  60 00 18 00 c8 00 00 06 09 20 a8 40 08     00:00:28.990  READ FPDMA QUEUED
  60 00 08 00 c0 00 00 06 0b 60 60 40 08     00:00:28.990  READ FPDMA QUEUED

Error 70 [5] occurred at disk power-on lifetime: 896 hours (37 days + 8 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 00 06 09 22 b0 46 08  Error: UNC at LBA = 0x060922b0 = 101262000

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  c8 00 00 00 58 00 00 00 09 22 b0 46 08     00:00:28.950  READ DMA
  60 00 58 00 d8 00 00 06 09 22 b0 40 08     00:00:28.950  READ FPDMA QUEUED
  60 00 10 00 d0 00 00 08 89 9e 20 40 08     00:00:28.950  READ FPDMA QUEUED
  60 00 18 00 c8 00 00 06 09 20 a8 40 08     00:00:28.950  READ FPDMA QUEUED
  60 00 08 00 c0 00 00 06 0b 60 60 40 08     00:00:28.950  READ FPDMA QUEUED

Error 69 [4] occurred at disk power-on lifetime: 896 hours (37 days + 8 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 00 06 09 22 b0 46 08  Error: UNC at LBA = 0x060922b0 = 101262000

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  c8 00 00 00 58 00 00 00 09 22 b0 46 08     00:00:28.915  READ DMA
  ef 00 02 00 00 00 00 00 00 00 00 40 08     00:00:28.915  SET FEATURES [Enable write cache]
  ef 00 aa 00 00 00 00 00 00 00 00 40 08     00:00:28.915  SET FEATURES [Enable read look-ahead]
  c6 00 00 00 01 00 00 00 00 00 00 40 08     00:00:28.915  SET MULTIPLE MODE
  ef 00 10 00 02 00 00 00 00 00 00 40 08     00:00:28.915  SET FEATURES [Enable SATA feature]

Error 68 [3] occurred at disk power-on lifetime: 896 hours (37 days + 8 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 00 06 09 22 b0 40 08  Error: UNC at LBA = 0x060922b0 = 101262000

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  60 00 58 00 18 00 00 06 09 22 b0 40 08     00:00:28.750  READ FPDMA QUEUED
  ef 00 02 00 00 00 00 00 00 00 00 40 08     00:00:28.750  SET FEATURES [Enable write cache]
  ef 00 aa 00 00 00 00 00 00 00 00 40 08     00:00:28.750  SET FEATURES [Enable read look-ahead]
  c6 00 00 00 01 00 00 00 00 00 00 40 08     00:00:28.750  SET MULTIPLE MODE
  ef 00 10 00 02 00 00 00 00 00 00 40 08     00:00:28.750  SET FEATURES [Enable SATA feature]

Error 67 [2] occurred at disk power-on lifetime: 896 hours (37 days + 8 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 00 06 09 22 b0 40 08  Error: UNC at LBA = 0x060922b0 = 101262000

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  60 00 58 00 d8 00 00 06 09 22 b0 40 08     00:00:28.585  READ FPDMA QUEUED
  60 00 10 00 d0 00 00 08 89 9e 20 40 08     00:00:28.585  READ FPDMA QUEUED
  60 00 18 00 c8 00 00 06 09 20 a8 40 08     00:00:28.585  READ FPDMA QUEUED
  60 00 08 00 c0 00 00 06 0b 60 60 40 08     00:00:28.585  READ FPDMA QUEUED
  60 00 48 00 b8 00 00 01 08 8f 18 40 08     00:00:28.585  READ FPDMA QUEUED

Error 66 [1] occurred at disk power-on lifetime: 896 hours (37 days + 8 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 00 06 09 23 08 46 08  Error: UNC at LBA = 0x06092308 = 101262088

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  c8 00 00 00 60 00 00 00 09 23 08 46 08     00:00:07.290  READ DMA
  60 00 e0 00 a0 00 00 06 09 11 c8 40 08     00:00:07.290  READ FPDMA QUEUED
  60 00 e8 00 98 00 00 06 09 10 e0 40 08     00:00:07.290  READ FPDMA QUEUED
  60 00 e0 00 90 00 00 06 09 10 00 40 08     00:00:07.290  READ FPDMA QUEUED
  60 00 e8 00 88 00 00 06 09 0f 18 40 08     00:00:07.290  READ FPDMA QUEUED

SMART Extended Self-test Log Version: 1 (1 sectors)
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       30%       896         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Commands not supported

Device Statistics (GP Log 0x04)
Page  Offset Size        Value Flags Description
0x01  =====  =               =  ===  == General Statistics (empty) ==
0x05  =====  =               =  ===  == Temperature Statistics (empty) ==
0x07  =====  =               =  ===  == Solid State Device Statistics (empty) ==
                                |||_ C monitored condition met
                                ||__ D supports DSN
                                |___ N normalized value

Pending Defects log (GP Log 0x0c) not supported

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x0001  2            0  Command failed due to ICRC error
0x0004  2            0  R_ERR response for host-to-device data FIS
0x0006  2            0  R_ERR response for device-to-host non-data FIS
0x0007  2            0  R_ERR response for host-to-device non-data FIS
0x0009  2            0  Transition from drive PhyRdy to drive PhyNRdy
0x000a  2            4  Device-to-host register FISes sent due to a COMRESET
0x000f  2            0  R_ERR response for host-to-device data FIS, CRC
0x0013  2            0  R_ERR response for host-to-device non-data FIS, non-CRC